The five stages of alert grief
Alert volume is the single most controllable factor in on-call health. Here's the pattern most teams go through.
Stage 1: Denial — "the pages are normal"
Engineers rotate through on-call. Each week has 15-30 pages. Team assumes this is just how on-call works.
Stage 2: Anger — "who set up this alert?"
Engineer gets paged at 3am for something that didn't matter. Complains loudly in Slack.
Stage 3: Bargaining — "can we silence this just for tonight?"
Alerts are silenced individually during incidents or for stretches. Maintenance windows proliferate. Original noisy alerts remain.
Stage 4: Depression — "on-call is hell"
Best engineers leave. Remaining engineers accept the misery. Hiring gets harder.
Stage 5: Acceptance — "let's actually fix this"
Someone insists on a change. Alert review happens. Noise drops 70%. On-call becomes sustainable.
The acceptance playbook
Week 1: measure
Export all pages from the last 90 days. Group by alert name. Identify the top 10 noisiest alerts (usually 60%+ of total volume).
Week 2: triage
For each top-10 alert:
- Was it actionable? (Could an engineer do something about it?)
- Did it map to a customer-impacting issue?
- What would've happened if it wasn't triggered?
If the answer to #1 is no, the alert shouldn't page. Route to ticket, email, or chat.
Week 3: fix
For each alert kept:
- Raise threshold if too sensitive
- Add dedup window if flapping
- Add required-duration condition (sustained for X min)
Week 4: new alert discipline
Every new alert goes through a template:
- What user impact does this represent?
- What should the engineer do when this fires?
- What's the dedup/threshold pattern?
Target: < 5 pages per shift
If you're > 10 pages per shift, you're burning out your team. < 5 is sustainable.
Tools
- Alert Noise Reducer for the top-10 analysis.